HVAC Sizing Calculator
Screening estimate of residential heating and cooling in BTU/h and nominal tons, where one ton is 12,000 BTU/h. The suggested size is for a heat pump and follows the larger load. For air conditioning only, use the cooling result. Not an ACCA Manual J load calculation.
This is a screening estimate for a US house. It is not an ACCA Manual J load calculation or a substitute for a licensed contractor.
Suggested nominal size
5.0 tons
Heating governs at 57,600 BTU/h.
Cooling
3.27 tons
39,273 BTU/h
Heating
4.80 tons
57,600 BTU/h
For a heat pump, the suggestion follows the larger load. For air conditioning only, use the cooling result. This is a screening estimate, not an ACCA Manual J load calculation.
Formula with your numbers
Cooling = 1800 × 21.82 × 1 × 1.000 × 1 × 1 = 39,273 BTU/h Heating = 1800 × 32 × 1 × 1.000 × 1 = 57,600 BTU/h Tons = BTU/h ÷ 12,000. Suggestion = smallest half-ton at or above the larger tons.
How this estimate works
A heat pump is sized in BTU per hour and sold in nominal tons. One ton is 12,000 BTU/h. The number on the outdoor unit is the capacity the manufacturer rates under a test condition, not a measurement of your house. This calculator estimates the heating load and the cooling load you are asking that capacity to cover. It uses a screening method of the kind a contractor might sketch before a full Manual J: floor area, a climate band, and a few adjustments you can see in the result.
Cooling starts from the rule of thumb that one ton serves about 400 to 750 square feet. Hotter houses sit toward 400. Milder climates and tighter houses can stretch toward 750. The climate table is this calculator’s point inside that range, written as BTU/h per square foot so the multiplication is obvious. Pick the band for your summer and winter. A mountain town and a desert city in the same state are different houses.
Insulation, ceiling height, glass, and duct location scale that starting point. The bare rule of thumb quietly assumes ceilings near eight feet, so a ten-foot ceiling is entered as 10/8 of the load. Glass is applied to cooling only. Winter sun is a gain, and treating it as extra heating load would push the heat pump the wrong direction. Ducts in a hot attic or a cold crawlspace leak and exchange heat with the outdoors. The attic factor is a flat uplift, a stand-in for the duct load Manual J would build from leakage, insulation, and surface area. It is not a measurement of your ducts.
The heat pump has to satisfy both seasons, and the larger screen governs. In a hot-humid house, cooling is usually larger. In a cold house, heating governs, and a unit chosen only from the cooling rule will be short on the design morning. Nameplate heating capacity is commonly rated near 47°F, and output falls as outdoor temperature falls. Compare the heating BTU on this page with the manufacturer’s capacity at your winter design temperature. A cold-climate model is built to hold more of its output then. Adding a full extra ton without that chart leads to short cycles and weak summer dehumidification.
Try the default house: 1,800 square feet, mixed climate, average insulation, eight-foot ceilings, typical glass, ducts inside the conditioned space. Cooling is 1,800 / 550 tons, about 3.3 tons. Heating is 1,800 × 32 BTU/h per square foot, 57,600 BTU/h, or 4.8 tons. Heating governs, and the nearest half-ton at or above 4.8 is 5 tons. That is a large machine for this floor area. Look at the envelope, or at two smaller systems, before anyone orders a single 5-ton heat pump. Change the climate to hot-humid and cooling becomes 1,800 / 450, or 4.0 tons, while heating drops to 1,800 × 20. Cooling governs. The example is here so you can audit the arithmetic.
This is not a Manual J, and it is not Manual S equipment selection. Manual J counts each surface, window direction, infiltration, people, appliances, and the real duct system. Manual S then limits how far the selected equipment may sit from that load, and the limit is not the same for an air conditioner and a heat pump. Use the result to frame the visit: roughly three tons or roughly five, ducts or ductless, cold-climate or not. Pair it with the CFM calculator if you want airflow, and with the replacement cost calculator if you want a planning range and a way to ask local contractors for quotes.
| Climate | Where it roughly fits | ft² per cooling ton | Heating BTU/h per ft² |
|---|---|---|---|
| Hot-humid | Gulf Coast, Florida, Hawaii | 450 | 20 |
| Hot-dry | Desert Southwest | 400 | 25 |
| Mixed | Mid-Atlantic, upper South, southern Midwest | 550 | 32 |
| Cold | Northeast, Upper Midwest, Mountain West | 650 | 45 |
| Very cold | Northern Plains, northern New England, Alaska | 750 | 58 |
| Input | Factor | Meaning |
|---|---|---|
| Insulation: Poor | 1.18 | Little insulation, original single-pane windows, noticeable drafts |
| Insulation: Average | 1 | Some attic insulation and mixed windows, typical of many 1980s–2000s houses |
| Insulation: Good | 0.86 | Attic and walls near current code, double-pane windows |
| Insulation: Excellent | 0.75 | Deep retrofit or a new high-performance envelope |
| Glass: Shaded or few windows | 0.95 | Applied to cooling only |
| Glass: Typical window area | 1 | Applied to cooling only |
| Glass: Large or west-facing glass | 1.12 | Applied to cooling only |
| Ducts inside conditioned space | 1.00 / 1.00 | Cooling factor / heating factor |
| Ducts in an attic or crawlspace | 1.15 / 1.10 | Flat uplift, not a measured duct loss |
| Ductless | 1.00 / 1.00 | No duct uplift |
| Ceiling height | height / 8 | Eight feet is the baseline the rules of thumb assume |
Questions homeowners ask
Is this the same as a Manual J load calculation?
No. Manual J is the ACCA room-by-room procedure that counts surfaces, windows, infiltration, people, and ducts. This page is a floor-area screen with climate and envelope adjustments, useful before that calculation and not a replacement for it.
Why is the heating estimate larger than the cooling estimate?
In mixed and cold climates the heating screen is often the bigger number, because a heat pump has to hold the house on the design winter morning, not only on a July afternoon. In hot climates the cooling screen usually governs. The page shows both and marks the larger one.
Should I round up to the next ton?
The suggestion is the nearest common half-ton size at or above the governing screen. Rounding up another full ton without a load calculation causes short cycles and weak dehumidification. If the suggestion is above five tons, treat that as a prompt to improve the envelope or split the system, then confirm with Manual J and Manual S.
What should I ask about cold weather capacity?
Ask for the manufacturer’s heating capacity at the local winter design temperature, and compare it with the heating BTU on this page. Capacity rated near 47°F will not all be available on a much colder morning. Cold-climate models are built to hold more of their output as the temperature drops.
Can I use this for a straight air conditioner?
Use the cooling BTU and cooling tons for an air conditioner screen. Ignore the heating result, or treat it as a furnace conversation instead. An air conditioner does not have a heating mode, and the cooling screen is still not a Manual J.
Related calculators
- BTU/hMini-split BTUEstimate mini-split BTU/h for each room, then match a standard nameplate from 6,000 to 36,000. A screening size, not a Manual J.
- CFMCFMEstimate airflow from tons, from sensible heat and temperature difference, or from a target air-change rate.
- RangeHVAC replacement costUS residential planning range for replacing a central air conditioner, gas furnace, ducted heat pump, or ductless mini-split. The default reuses existing ducts. Replacing main trunks is a higher duct multiplier, not a full new duct installation. The ZIP is for the quote request only. It does not change the math or list local contractors.