Water Heater Size Calculator

Add up peak-hour hot water for a storage heater’s first hour rating, and the simultaneous flow and temperature rise for a tankless heater.

Storage sizing uses the AHRI peak-hour worksheet. Low-flow gallons are this calculator’s allowances, marked separately from the AHRI column. Tankless flow is not a manufacturer chart.

Storage heater, peak hour

Use during the busiest hourTimesGallons each
ShowerAHRI worksheet: 20 gal
BathAHRI worksheet: 20 gal
ShavingAHRI worksheet: 2 gal
Hands and face washingAHRI worksheet: 4 gal
Hair shampooAHRI worksheet: 4 gal
Hand dishwashingAHRI worksheet: 4 gal
Automatic dishwasherAHRI worksheet: 14 gal
Food preparationAHRI worksheet: 5 gal
Wringer clothes washerAHRI worksheet: 26 gal
Automatic clothes washerAHRI worksheet: 32 gal

Peak hour demand

0 gallons

Enter the uses that happen in the same hour.

Worksheet total

Total = 0 gallons

Tankless heater, simultaneous flow

  • gpm
  • gpm
  • gpm
  • gpm
  • gpm
°F

DOE says to assume 50°F unless you know the real inlet. Northern winter mains are often colder.

°F

120°F is the DOE figure for most household uses.

Simultaneous flow

3.25 gpm

Only the fixtures you checked.

Temperature rise

70°F

120°F delivery minus 50°F inlet.

Formula with your numbers

Flow = 2.5 shower + 0.75 bathroom faucet = 3.25 gpm Rise = 120 − 50 = 70°F

DOE’s sizing guide says a 70°F rise is typically available at about 5 gpm on gas demand heaters and about 2 gpm on electric ones. That is an illustration, not your model. Read the manufacturer’s chart at a 70°F rise.

How this estimate works

A storage water heater is sized by first hour rating, not by the number painted on the tank. First hour rating is the gallons of hot water the heater can supply in an hour, starting full, including what the burner or element can recover during that hour. A 50-gallon gas heater often has a first hour rating well above 50 because the burner keeps up. A 50-gallon electric heater is often closer to the tank volume because recovery is slower. The EnergyGuide label lists first hour rating for conventional storage heaters. Heat pump water heaters may list it in the product data instead. Shop for that rating, then check the tank volume.

The worksheet is the AHRI peak-hour method that DOE sizing guidance has long used. Count the single busiest hour, not the whole day. Published gallons, assuming no conservation, are 20 for a shower, 20 for a bath, 2 for shaving, 4 for hands and face, 4 for shampoo, 4 for hand dishwashing, 14 for a dishwasher, 5 for food preparation, 26 for a wringer washer, and 32 for an automatic clothes washer. Three showers, one shave, one shampoo, and one hand dishwashing is 60 + 2 + 4 + 4 = 70 gallons. DOE says to look for a first hour rating within about 1 or 2 gallons of that peak.

The low-flow button does not pretend those AHRI numbers changed. It substitutes planning allowances where fixtures actually got more efficient, and it leaves a note on each one. A shower drops from 20 to 10 as a short shower at a 2.0 gpm showerhead. A tub stays at 20. An automatic dishwasher drops from 14 to 6, and an automatic washer from 32 to 14, as allowances for modern machines. You can type any gallon figure yourself. If you do, the total is your worksheet, not AHRI’s. Using the high, no-conservation column is the safer screen for a heater that may stay in the house for more than a decade, which is why the AHRI notes recommend the high end of the range.

Tankless heaters are sized by flow and temperature rise, which is the other half of this page. List the fixtures that will run at the same time and add their gallons per minute. DOE’s own example is a 2.5 gpm shower plus a 0.75 gpm faucet, 3.25 gpm together. Rise is the delivery temperature minus the inlet temperature. Unless you know the inlet, DOE says to assume 50°F, and 120°F is the delivery temperature it cites for most uses. That is a 70°F rise. Groundwater in the northern US is often colder than 50°F in winter, and groundwater in the deep South can be warmer. Edit the inlet. Do not leave 50°F in a climate where the winter main is closer to 40°F.

DOE notes that a 70°F rise is typically available at about 5 gpm on gas demand heaters and about 2 gpm on electric ones. That is an illustration in the federal sizing guide, not a model to buy. Use the manufacturer’s chart at your rise. A flow measured at a mild 35°F rise will not hold when the inlet is cold. Electric tankless units often need a large electrical service, which this page does not size.

A heat pump water heater with a tank is still chosen by first hour rating. The room also has to meet the manufacturer’s volume requirement, and condensate needs a drain. The replacement cost page can send a water-heater quote request. It does not know your utility rate or local code.

Gallons per use: AHRI worksheet versus this calculator’s low-flow allowances
UseAHRI gallonsLow-flow allowance
Shower2010
Bath2020
Shaving22
Hands and face washing42
Hair shampoo44
Hand dishwashing44
Automatic dishwasher146
Food preparation55
Wringer clothes washer2626
Automatic clothes washer3214

Request local quotes

Name, ZIP, and a phone or email. This does not reserve a price.

Enter a phone number, an email, or both.

Questions homeowners ask

Is first hour rating the same as tank size?

No. Tank size is the stored volume. First hour rating is what the heater can deliver in the first hour, including recovery. Gas storage heaters often deliver more than their tank volume in that hour. Electric storage heaters often deliver less extra, because the elements recover more slowly.

Which gallon column should I use?

The AHRI column assumes no water conservation and matches the published worksheet, including the 70-gallon example. The low-flow column is this site’s planning allowances for efficient fixtures and is labeled as such. Editing a number yourself makes the total your own worksheet. The safer purchase screen is a first hour rating that can cover the higher total.

What flow rate does a tankless water heater need?

Add the gallons per minute of the fixtures that will run together. A DOE example is 2.5 gpm for a shower plus 0.75 gpm for a faucet. Then compare that flow with the manufacturer’s chart at your temperature rise, not at a milder rise than your winter inlet will require.

Should the water heater be set to 140°F?

The sizing default here is 120°F delivery, which is the figure DOE cites for most household uses. Higher storage temperatures increase available hot water and scald risk. Dishwashers that heat their own water do not need 140°F from the tank. Follow the manufacturer and local code, and use a mixing valve if storage temperature is raised.

Does this size a heat pump water heater?

Use the first hour rating for a heat pump water heater with a tank, the same way you would for any storage heater. Also confirm the room volume the manufacturer requires and a place for condensate. This worksheet does not check either one.