HVAC Replacement Cost Calculator
US residential planning range for replacing a central air conditioner, gas furnace, ducted heat pump, or ductless mini-split. The default reuses existing ducts. Replacing main trunks is a higher duct multiplier, not a full new duct installation. The ZIP is for the quote request only. It does not change the math or list local contractors.
These are typical planning estimates from the bands in the form. They are not a national price survey, not a bid, and not a promise that a contractor will match the range.
Applied to air conditioners, heat pumps, and mini-splits. Not applied again to the furnace band. These planning multipliers are not SEER2 ratings.
1.00 reuses existing ducts. 1.30 replaces main trunks and is not a full new duct installation.
1.00 unless you already know your market runs higher or lower. This is not a regional index.
Edit the planning bands
Central air, per ton
Standard furnace, installed
Condensing furnace, installed
Ducted heat pump, per ton
Mini-split, first zone
Mini-split, each added zone
Permit
Electrical upgrade
Planning range
$7,500 – $13,500
Typical estimate built from the bands and multipliers above. Not a quote.
- Ducted heat pump: $7,500 – $13,5003 tons × $2,500–$4,500 per ton × 1 efficiency × 1 ducts × 1 labor
How the total is built
Install lines are band × capacity (when the band is per ton or per added zone) × the multipliers that apply. Permit and electrical bands are added afterward, and only if checked.
The default duct multiplier of 1.00 is a replacement that reuses existing ducts. 1.10 is minor repairs. 1.30 replaces main trunks and is not a full new duct installation. A mini-split does not use the duct multiplier. Permit and electrical allowances are included only if checked. Line sets beyond a simple install, cranes, pads, condensate pumps, flue changes, asbestos, and drywall are not separate lines.
Efficiency choices of 1.00, 1.15, and 1.30 are planning multipliers, not SEER2 ratings. The ZIP on the quote form does not change this range and does not list local contractors.
Do not subtract the federal energy efficient home improvement credit (IRC §25C) from this range. IRS FS-2025-05 says that credit is not allowed for property placed in service after December 31, 2025, so do not deduct it from a 2026 installation cost. Earlier eligibility is not automatic. State and utility incentives are not estimated here and are not ruled out.
The ZIP is for this quote request only. It does not change the planning range, and this page does not list local contractors.
How this estimate works
This page builds a planning range. It does not report the average price of an air conditioner, a furnace, a heat pump, or a mini-split, because this site has not run a price survey and will not invent one. Every dollar figure starts as a round band written in the form. You can open the assumptions and change the low and the high before you read the total. The total is the sum of those bands after a few multipliers, which are also written out in the result. If a contractor’s number falls outside the range, the range was the wrong assumption, not a fact the contractor has violated.
Capacity equipment is estimated per ton. The default central-air band is $1,800 to $3,200 per ton, and the default ducted heat pump band is $2,500 to $4,500 per ton, for equipment and a straightforward install with ducts reused. A gas furnace is a flat band rather than a per-ton band: $3,200 to $5,800 for a standard-efficiency furnace and $4,500 to $8,200 for a condensing furnace. A mini-split uses $3,500 to $7,000 for the first indoor unit and outdoor unit, plus $1,800 to $3,500 for each added indoor unit. Those are budgeting figures chosen so the math is easy to audit. Replace them with numbers from a local bid if you have one.
Three multipliers sit on the install subtotal. The efficiency multiplier is 1.00, 1.15, or 1.30 for standard, higher-efficiency, or premium cold-climate equipment. They are not SEER2 ratings. It is applied to air conditioners, heat pumps, and mini-splits. It is not applied to the furnace, because the furnace band you picked is already the efficiency choice. The duct multiplier is 1.00 if the ducts stay, 1.10 for minor repairs, and 1.30 if main trunks are being replaced. That is not a full new duct system. It is not applied to a ductless system. The labor multiplier defaults to 1.00. It is a factor you set because you know your market, not a regional cost index. Leave it alone unless you have a reason.
Permit and electrical work are flat bands added after those multipliers, and only if you check them. The permit default is $150 to $500. The electrical default is $800 to $3,000 for a new circuit or panel work. Unchecked, they add nothing. A long line set, a crane, a condensate pump, a pad, a new flue on a non-condensing swap, asbestos, and drywall are not in the model. Do not subtract IRC §25C. IRS FS-2025-05 does not allow that federal credit for property placed in service after December 31, 2025, including a 2026 installation. State and utility incentives are separate and are not estimated.
Read the lines, not only the span. A 3-ton central air conditioner at the default band, standard efficiency, ducts reused, and labor at 1.00 is 3 × $1,800 to 3 × $3,200, or $5,400 to $9,600, before any permit or electrical box. The width is intentional. Two bids inside a wide band can both be honest. Two bids far apart usually mean the scope is not the same.
The form sends a quote request. It does not reserve a price, and it does not schedule an install. You can attach the planning range as a note so the contractor sees the scope you had in mind. Use the heat pump, mini-split, and water heater calculators to decide that scope first. A useful request says what equipment, what size screen, and what ZIP. A licensed contractor still has to look at the house, the ducts, the electrical service, and the load.
| Scope | Default band |
|---|---|
| Central air conditioner | $1,800–$3,200 per ton |
| Ducted heat pump | $2,500–$4,500 per ton |
| Standard gas furnace | $3,200–$5,800 installed |
| Condensing gas furnace | $4,500–$8,200 installed |
| Mini-split, first indoor unit | $3,500–$7,000 |
| Mini-split, each added unit | $1,800–$3,500 |
| Permit, if checked | $150–$500 |
| Electrical upgrade, if checked | $800–$3,000 |
Cost of AC replacement, and “near me”
The cost of AC replacement and “AC replacement near me” are the same decision for most homeowners: what a new central air conditioner might cost at this house. Choose “Central air conditioner” and a tonnage. At the default band, 3 tons, standard efficiency, ducts reused, and labor left at 1.00, the line is $5,400 to $9,600 before any permit or electrical allowance you turn on. A furnace, ducted heat pump, or mini-split uses the other bands on the same form. The math does not change with the ZIP.
This page is not a directory and not a local price list. It does not name contractors, show who serves a city, or publish a different range for each ZIP. Labor is a multiplier you set, not an index of your market. The quote form asks for a ZIP so the operator can pass the request to heating and cooling contractors they work with. Sending it does not mean a contractor covers that ZIP, and it does not reserve a price. If you already have a bid, type those figures into the planning bands and compare the scope.
Size the job before you price it. The HVAC sizing calculator screens tons for a ducted system. The mini-split BTU calculator screens room nameplates when the equipment is ductless. The quote form is on this page.
Questions homeowners ask
Are these average installed prices?
No. They are planning bands written into the calculator so you can see the arithmetic. They are not a national average, not a price index, and not a quote. Change the low and high figures if you have local numbers.
Why is the range so wide?
The default bands are already wide, and the efficiency, duct, and labor multipliers stretch them further. Equipment brand, job difficulty, and what is included in “install” move real bids by as much as the band. A wide range is a better budgeting tool than a fake precise average.
What costs are left out?
Line-set length beyond a simple install, cranes, pads, condensate pumps, flue changes, asbestos, drywall, and incentive paperwork are not line items unless you fold them into a band yourself. Permits and electrical work are included only when those boxes are checked.
Does submitting the form lock in a price?
No. The form is a request to be contacted about a quote. The range on the page is not an offer. Any price comes from a contractor after they see the house and the scope.
Who will contact me?
You are agreeing that this site and heating, cooling, and plumbing contractors it works with may call, text, or email you about the request. The request is stored for the operator and, if a lead webhook is configured, forwarded there. Consent is not required to use the calculators.
What is the cost of AC replacement on this page?
For a central air conditioner only, the default planning band is $1,800 to $3,200 per ton before the efficiency, duct, and labor multipliers. A 3-ton unit at those defaults and a labor multiplier of 1.00 is $5,400 to $9,600. That span is the same in every ZIP. It is not the cost of AC replacement in your town. Replace the band if you have a bid.
Does this find AC replacement near me?
No. There is no map, no contractor list, and no ZIP-based price. The quote form collects a ZIP so a request can be forwarded to contractors the operator works with. Sending it does not mean someone serves that ZIP, and it does not change the planning range.
Related calculators
- TonsHVAC sizingScreening estimate of residential heating and cooling in BTU/h and nominal tons, where one ton is 12,000 BTU/h. The suggested size is for a heat pump and follows the larger load. For air conditioning only, use the cooling result. Not an ACCA Manual J load calculation.
- BTU/hMini-split BTUEstimate mini-split BTU/h for each room, then match a standard nameplate from 6,000 to 36,000. A screening size, not a Manual J.
- GallonsWater heater sizeAdd up peak-hour hot water for a storage heater’s first hour rating, and the simultaneous flow and temperature rise for a tankless heater.